FMPR contactless controller
Controller dedicated for ERS/EPR A contactless controller dedicated for control only clutches, brakes and cell pack series brakes. The basic circuit consists of power, power switching, and operation control. |
|
Dimensional outline drawing
Specifications
Type | TMP-40D | |
Input voltage AC V | 100/110·200/220 | |
Fuse capacity A | 5 | |
Clutch output voltage DC V | 24 | |
Brake output voltage DC-V | 1-24±10% | |
Capacity W | 35(Clutch side), 35(Brake side) | |
Rating | Continuous | |
Excitation method | With inverse excitation by capacitor for both clutch/brake | |
Structure | Steel plate, wall mounting, protective enclosure | |
Weight kg | 3.4 | |
Painting color | Munsell 7.5BG6/1.5 |
(Note)
1 The capacity shows the total capacity of the clutch/brake
2 It is not necessary to connect a varistor as a discharge circuit.
External connection diagram
(Note)
1 PS terminal is for switching CL/MB using an external power source. See the operation manual for details.
2 F terminal; is for freeing CL/MB by an external signal. See the operation manual for details.
3 Only current of several milliamps can be used for the external signal so ensure an appropriate input.
Layout drawing of Switch, variable resistance and fuse